Bio-Nano Sensor and Measurement for Direct DNA Oxidation 

Researcher  and author: Dr.   (   Afshin Rashid)


Note: Signal measurement Electrochemical methods are very suitable for detecting direct DNA oxidation because electrochemical reactions directly generate  electronic signals and therefore do not require expensive converters. 

In addition, in this process, because the order of the immobilized game  can be limited to only a series of electrode substrates, the act of tracking is performed by a series of inexpensive electrochemical analyzes. Electrochemical sensors are used to perform clinical or environmental tests;  The basis of the sensitivity of electrochemical signals to direct oxidation or interval catalysis of DNA is also based on the reduction reactions of reporter molecules or enzymes. Various methods are used to measure the  signal electrochemically. The basis of signal measurement in direct DNA electrochemistry is based on the oxidation reaction and DNA reduction at a mercury electrode, so the amount of oxidized and reduced DNA is proportional to the amount of DNA hybridized with the probe. In addition to the old methods of direct DNA reduction, a method called Stripping Adsorption Voltammetry is used for direct oxidation of DNA, which is a very sensitive method. In the direct electrochemical method, purines are oxidized by materials such as carbon, indiomethin oxide (ITO), gold, and polymer-coated electrodes. Although the direct electrochemical method is a very sensitive method, its application is complex because  direct oxidation of DNA requires a high potential ground current. Advanced mathematical and numerical methods are also  needed to measure each signal. Of course, new methods have been designed to eliminate the interference that occurs in the field with the help  of physical methods.

 Target DNA is detected by  probes fixed on magnetic beads. In this method, after the DNA of the probe collides with the target DNA, the magnetic grains are separated in solution. The collected  DNAs are depiurinated in acidic solution, and the free guanine and adenine nucleosides are collected and analyzed by absorption voltmetry A similar method has also been reported using direct oxidation of guanine, which  was able to detect a specific mutation in DNA fragments amplified by PCR. Another method is to use a peptide nucleic acid probe. By using these probes, the hybridization operation is performed more firmly  and point mutations in the target DNA can be detected with this method.In the indirect electrochemical method of DNA, electrochemical interfaces are used for DNA oxidation. A  very effective specific method is the use of polypyridyl complexes (RUII) and IIO, which electrochemically oxidize guanine by nanomolecules  Trace a sequence of three nucleotides by this method. This method, along with PCR-rt, can be used to overexpress genes in tumor samples and is highly sensitive. In the same way, chemically altered organic bases are introduced into the PCR product and the  DNA obtained by some methods is identified. Although this method is very sensitive, it is not yet clear whether this method is  suitable for clinical diagnoses. One of the advantages of this method is that it is not complicated.

Several methods were used to detect target DNA with reductant active reporter molecules labeled with the  molecule. Using physical methods, the order of the labeled game up to the range  in this method includes measuring the assay sandwich component Three, in which case the  regenerated labeled material is attached to a synthetic DNA fragment, which is a DNA fragment. Attaches to the probe-target complex , in other words, the reduced regenerated material is attached to a synthetic fragment, which is attached to or attached to the  probe-target complex, in which case a change is needed in the target DNA. Is created  and destroyed, which causes the probe and the sequence of the marked game to be put together. Labeling is the use of a ferrosin-labeled probe placed on a gold electrode. Using  this technique, the target DNA can be encapsulated and a change can be made in the ferrosin molecule due to the contact made, which gives a signal to the gold electrode, and this signal is measured as a Faraday current. 


Researcher  and author: Dr.   (   Afshin Rashid)

PhD in Nano-Microelectronics